PartNumber | LNK564DN-TL | LNK564DN | LNK564DN-100I |
Description | AC/DC Converters 3 W (85-265 VAC) 3 W (230 VAC) | AC/DC Converters 3 W (85-265 VAC) 3 W (230 VAC) | |
Manufacturer | Power Integrations | Power Integrations | - |
Product Category | AC/DC Converters | PMIC - AC DC Converters, Offline Switchers | - |
RoHS | Y | - | - |
Mounting Style | SMD/SMT | SMD/SMT | - |
Package / Case | SO-8C | - | - |
Output Voltage | 6 V | 5.8 V | - |
Output Power | 3 W | 3 W | - |
Input / Supply Voltage Min | 85 VAC | - | - |
Input / Supply Voltage Max | 265 VAC | - | - |
Switching Frequency | 100 kHz | 100 kHz | - |
Duty Cycle Max | 70 % | - | - |
Operating Supply Current | 220 uA | 160 uA | - |
Minimum Operating Temperature | - 40 C | - | - |
Maximum Operating Temperature | + 150 C | + 150 C | - |
Output Current | 330 mA | 148 mA | - |
Series | LNK56 | LinkSwitchR-LP | - |
Packaging | Reel | Tube Alternate Packaging | - |
Number of Outputs | 1 Output | 1 Output | - |
Type | Off Line Converter | Off-Line Switcher | - |
Brand | Power Integrations | - | - |
Product Type | AC/DC Converters | - | - |
Factory Pack Quantity | 2500 | - | - |
Subcategory | PMIC - Power Management ICs | - | - |
Tradename | LinkSwitch-LP | LinkSwitch | - |
Unit Weight | - | 0.017870 oz | - |
Operating Temperature Range | - | - 40 C to + 150 C | - |
Package Case | - | SO-8 | - |
Operating Temperature | - | -40°C ~ 150°C (TJ) | - |
Mounting Type | - | Surface Mount | - |
Supplier Device Package | - | SO-8C | - |
Power Watts | - | 3W | - |
Output Isolation | - | Isolated | - |
Internal Switch s | - | Yes | - |
Voltage Breakdown | - | 700V | - |
Topology | - | Flyback | - |
Voltage Start Up | - | - | - |
Voltage Supply Vcc Vdd | - | - | - |
Duty Cycle | - | 70% | - |
Frequency Switching | - | 100kHz | - |
Fault Protection | - | Current Limiting, Open Loop, Over Temperature, Short Circuit | - |
Control Features | - | - | - |
Duty Cycle Max | - | 70 % | - |
Input Supply Voltage Min | - | 85 VAC | - |
Input Supply Voltage Max | - | 265 VAC | - |